single-header-banner

How to Use Serological Pipettes

How to Use Serological Pipettes

A serological pipette is a consumable that can accurately and accurately transfer or extract a certain liquid. To use a serological pipette correctly, you need to prepare the following materials: White reagent bottle, 2 small beakers, 2 Erlenmeyer flasks, filter paper, serological pipette and rack, ear cleaning ball.

https://www.sdlabio.com/serological-pipettes/

Steps:

1. Check Check whether the accuracy level of the pipette meets the usage requirements → Whether the markings and scale lines of the pipette are clear and whether the position of the scale lines is correct → Whether the pipette is correct and within the validity period → Check the cleanliness of the pipette → Check Check whether the pipette is damaged. If it is damaged, it cannot be used.

⒉Pinch the pipette with your right hand for washing, and hold the ear cleaning ball with your left hand → Hold the ear cleaning ball in your palm, with the tip facing down, and hold the ear cleaning ball tightly. Exhaust the air in the ball → Insert the tip of the ear cleaning ball into or close to the top of the pipette (be careful not to leak) → Slowly release your left hand and suck the washing liquid into the pipe. The sucked washing liquid is about 1 hour in the pipette. /3, quickly block the top of the pipette with your right finger, and place the pipette horizontally → Hold both ends of the pipette with both hands and rotate the pipette so that the washing liquid covers the entire inner wall of the tank. After soaking for a while, pour out the washing liquid → rinse with tap water, and rinse with distilled water three times → place it on a clean pipette rack for later use.

3. Aspirate and shake the liquid to be aspirated, pour a small amount of the liquid to be aspirated into a clean and dry small beaker → use filter paper to absorb the water inside and outside the cleaned pipette tip, and insert it into the small beaker to absorb the liquid → use Absorb the liquid in the same way as during washing → When the liquid reaches 1/3 of the pipette capacity, immediately press the mouth of the pipette with your right index finger, take out the pipette, hold it horizontally and rotate it so that the liquid infiltrates the entire inner wall of the pipette. When the liquid flows to 2-3cm above the graduated line, hold the pipette upright and drain the liquid.

Shandong Labio’s disposable serological pipettes are made of highly transparent polystyrene.

1. Disposable pipettes are made of highly transparent polystyrene material. The unique design of the pipe mouth can be adapted to almost all brands of pipettes. Products are manufactured in 100,000-level clean production workshops. The entire production process is controlled and managed in accordance with the ISO13485: 2016 quality management system to ensure product quality.

2. Currently, the company provides six capacity specifications of gamma ray sterilized and non-sterilized products for customers to choose from. Capacity specifications: 1.0ML, 2.0ML, 5.0ML, 10.0ML, 25.0ML, 50.0ML, calibration rate within ±2%.

3.1.0ML, 2.0ML and 5.0ML pipettes adopt cone head stretching method.

4.10.0ML, 25.0ML and 50.0ML pipette heads/nozzles are welded to the pipe body using ultrasonic welding. Minimize the adhesion of liquid to the pipe wall and improve sampling accuracy.

5. The hard two-way scale design ideally meets the requirements of sample addition and subtraction. The clear and concise scale facilitates the absorption and reading of liquids.

6. Filter plug with filter element, gamma ray sterilization, no pyrogen.


Post time: Oct-09-2023